There is a programming error in the calculations of "line purity". The error affects any targets with more than one line; the more lines the worse the error. The plots and tables for "line purity" from the online catalog should not be used until corrections have been made.
Set 1: K-edge group, unfiltered. Target Voltages (kV): 15.418 23.127 30.836 38.545 PEIS Source Model: table plot1 plot2 At Focal Plane: table plot1 plot2 ACIS, Backside-Illuminated: table plot1 plot2 ACIS, Frontside-Illuminated: table plot1 plot2 HRC, CsI MCP + UV shield: table plot1 plot2
Set 2: K-edge group, Co filter. Target Voltages (kV): 15.418 23.127 30.836 38.545 Filter Thickness (micron): 0 18.8 37.7 75.3 113. 151. 188. PEIS Source Model (filtered): table plot At Focal Plane: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) ACIS, Backside-Illuminated: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) ACIS, Frontside-Illuminated: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) HRC, CsI MCP + UV shield: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb)
Set 3: K-edge group, Fe filter. Target Voltages (kV): 15.418 23.127 30.836 38.545 Filter Thickness (micron): 0 23.2 46.3 92.7 139. 185. 232. PEIS Source Model (filtered): table plot At Focal Plane: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) ACIS, Backside-Illuminated: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) ACIS, Frontside-Illuminated: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) HRC, CsI MCP + UV shield: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb)
Set 4: L-edge group, unfiltered. Target Voltages (kV): 1.558 2.337 3.116 3.895 PEIS Source Model: table plot1 plot2 At Focal Plane: table plot1 plot2 ACIS, Backside-Illuminated: table plot1 plot2 ACIS, Frontside-Illuminated: table plot1 plot2 HRC, CsI MCP + UV shield: table plot1 plot2
Set 5: L-edge group, Co filter. Target Voltages (kV): 1.558 2.337 3.116 3.895 Filter Thickness (micron): 0 0.584 1.17 2.34 3.5 4.67 5.84 PEIS Source Model (filtered): table plot At Focal Plane: table plot line purity - table plot (Ll) plot (Leta) plot (La) plot (Lb) ACIS, Backside-Illuminated: table plot line purity - table plot (Ll) plot (Leta) plot (La) plot (Lb) ACIS, Frontside-Illuminated: table plot line purity - table plot (Ll) plot (Leta) plot (La) plot (Lb) HRC, CsI MCP + UV shield: table plot line purity - table plot (Ll) plot (Leta) plot (La) plot (Lb)
Editor: Dr. Douglas Swartz System Administrator: Mr. Bob Dean Privacy Policy and Important Notices Accessibility Statement |